User's Guide

Restrictions:
1. Do not mount the unit on any
kind of metal surface.
2. Do not mount any input cable
next
to the antenna (see figure).
Meter types:
1. There are two main types of meters:
2. Meters that produces a ‘Passive
Pulse’.
3. Meters that produces an ‘Active-
Pulse’ (known also as-‘’Pulse
Generator’).
Technical Specifications:
Operating Voltage
815 VDC
Standby Current
30µA max.
Tx Current
0.8A max.
Power Output
3W
Freq. Stability
0.5ppm at
operating temp.
range
Operating Temp.
-22F 120F
(-30C 60C)
Storage Temp.
-40F 158F
(-40C 70C)
Weight
0.5 lb.
(230 gr.)
Wiring:
1. Connect the two polls of the Meter
input cable to the meter using a self-
stripping insulated connector (like 3M-
Scotchlock or equivalent).
2. Polarity: if a ‘Passive Pulsetype meter
is connected, there is no polarity so the
wires can be connected in any order, if
an ‘Active Pulse’ type meter is
connected, there is a polarity and the
wires have to be connected in the
following order: Red wire to the
POSITIVE (+) poll and the Black wire
to the NEGATIVE (-) poll,
(see figure 4).
THE MANUFACTURER IS NOT
RESPONSIBLE FOR ANY RADIO OR
TV INTERFERENCE
CAUSED BY UNAUTHORIZED
MODIFICATIONS TO THIS
EQUIPMENT. SUCH
MODIFICATIONS COULD VOID
THE USER’S AUTHORITY TO
OPERATE THE EQUIPMENT.
Figure 4: Wiring
RF EXPOSURE INFORMATION:
The antenna gain used with this transmitter should be 0dBi or less. All persons should
maintain a minimum safety separation distance of 45.45 cm (0.4545 m)