Installation Instructions
Vinyl
Rainware
System
Brown
Clay
Khaki
Gray
Sandstone
White
HORIZONTAL COMPONENTS
Components Parts Description
Qty
Req.
K1
Gutter
10 ft. lengths. Gutter may be cut to fit 
any size. Divide the total lineal feet of the 
project by 10 to determine the number of 
gutter pieces required.
K2
Left
End Cap
For capping the left open end of a 
gutter. Also fits on drop outlet. Must be 
cemented (A1) to the end of the gutter.
K3
Drop 
Outlet for 
Downspout
Allows for free thermal expansion 
of gutter while providing outlet to 
downspout. One required for each 
downspout assembly. Do not cement. 
Two (2) K31 screws required.
K4
Inside 
Corner
For internal corner joining of gutter 
sections. Must be cemented (A1) to the 
end of the gutters.
K5
Hanger
Firmly supports gutter sections while 
allowing for free expansion. One required 
for every 24" of gutter. Do not cement. 
Two (2) A2 screws required.
K6
Outside 
Corner
For exterior corner joining of gutter 
sections. Must be cemented (A1) to the 
end of the gutters.
K7
Connector
For joining two gutter sections. 
Must be cemented (A1) to the two 
sections of gutters.
Vinyl Rainware System
Do it yourself  •  Durable  •  Easy to install
HORIZONTAL COMPONENTS
Components Parts Description
Qty
Req.
K8
Right
End Cap
For capping the right open end of a 
gutter. Also fits on drop outlet. 
Must be cemented (A1) to the end of 
the gutter.
K9
Expansion 
Connector
Must be used on any side where there 
is 25 ft. or more between two corner 
components and no drop outlet. Allows 
for free expansion of gutter. Do not 
cement. Two (2) K31 screws required.
K10
Leaf Guard
Keeps gutter free of leaves. Available in 
5 ft. lengths.
K11
Wedge*
Used to adapt brackets and drop 
outlet to inward slanted fascia. Will 
compensate for roof pitches: 4/12 and 
6/12. Do not cement. Must be used with 
gutter bracket.
*SO - Special Order
Snap Together
Do-It Yourself
The K-Snap Leaf Guard is 
the perfect complement to 
your rainware installation. 
It keeps leaves and large 
debris out of your gutters.
manufactured by:
Snap Together - Do It Yourself
Durable - Easy to Install
STEP 1:
Install drop outlet (K3) at predetermined downspout location. Install a bracket (K5) 
at highest point on fascia board at farthest point from drop outlet. Always slope 
down to downspout location. Mark chalk line and position brackets every 24". 
Slope should be 1/4" per 10 ft. End cap (K2 or K8) may be attached directly to 
drop outlet if at end of a gutter run. If gutter continues around corner, position 
brackets at same height and no closer than 12" from corner.
STEP 2:
Lightly sand surfaces to receive cement with 100 grit paper. Surfaces should be 
clean and dry. Minimum temperature should be 32° F. Drying time of cement is 
approximately 30 seconds. Use Plastmo cement only. Install end caps while still 
on ground. Small guides will keep it in place while cement dries. For corners apply 
cement in zig-zag pattern from front to back.
STEP 3:
Install gutter section with attached corner (K4 or K6) and/or end cap (K2 or K8) 
onto brackets. Push rear edge of gutter up into bracket then snap front top of 
gutter over front tip.
STEP 5:
Join gutter sections at roof level. Apply cement on cleaned connectors (K7) from 
front to back. Hook connector onto rear edge of gutter, and then press connector 
onto front of gutter so “Lock Rim” snaps into place.
STEP 7:
Make sure all cemented fittings are at 
least 2" away from brackets.
Install elbow (D2) onto drop outlet. Measure downspout and cut to size between 
elbows. Install third elbow at bottom of downspout using downspout bracket (D3) 
as shown. Also install downspout bracket at top of downspout and at downspout 
connector (if necessary). 
STEP 8:
On particularly long runs you should 
install an expansion connector (K9). 
This is only needed when there is no 
downspout, therefore, no drop outlet, 
and a corner at either end of gutter run 
and there is more than 25 ft. of gutter 
between corners. See the instructions 
included with unit.
STEP 4:
See temperature lines inside the drop outlet for proper placement of gutter. 
Note: Do not cement gutter to drop outlet. Second side of corner can now be 
cemented to clean surface of gutter. Engage gutter by pushing it up the back edge 
of corner, then push front of gutter so that “Lock Rim” snaps into place.
Leaf Guard
Vinyl Rainware System
KSP-M15A ©2015 KP Building Products  www.KPproducts.com
K2
Left End Cap
K3
Drop Outlet
D3
Downspout 
Bracket
D4
Downspout
Connector
D1
Downspout
D2
Elbow 75°
K4
Inside Corner
K1
K-Snap Gutter
K5
Hanger
K6
Outside Corner
K7
Connector
K8
Right End Cap
Complete K-Snap Rainware System
VERTICAL COMPONENTS
Components Parts Description
Qty
Req.
D1
Downspout
10 ft. lengths. May be cut to size for use 
between elbows. Generally one length 
required for each story. Do not cement.
D2
Elbow 
(75°)
Two are required for each downspout 
assembly to bring downspout from 
the fascia overhang to the wall. A third 
may be used at base of downspout. 
Do not cement.
D3
Downspout 
Bracket
For securing downspout to the wall. 
Use two for every length of downspout. 
Do not cement. Two (2) K31 screws 
required.
D4
Downspout 
Connector
To join two lengths of downspout. 
Also used for joining downspout to 
drop outlet where there is no overhang. 
Do not cement.
D5
Swing Up 
Outlet
Installed at the base of the Downspout to 
divert water from the building; swings up 
for mowing, etc. Do not cement.
Each component is designed 
and manufactured for durability 
and ease of installation.
NOW AVAILABLE IN 
VARIOUS COLORS.
ACCESSORIES
Components Parts Description
Qty
Req.
A1
Cement
(5 fl. oz.)
Use on surfaces to be permanently 
“welded”. One tube required for every 
100 ft. Use Plastmo cement only.
A2
Screws
#10 x 1 3/4"
20/bag
For mounting brackets, drop outlet 
and expansion connector to building. 
5/16" Hex and slot drive, plated.
K10