Instruction Manual

KRAMER: SIMPLE CREATIVE TECHNOLOGY
Kramer Package Upload Process
4
4 Kramer Package Upload Process
You can upload any of the following files:
KFW, KFWS : Firmware binary file
RBF: FPGA binary file
MF, MFS: Memory File
KPT: the Kramer Package that includes one or more files to upload to a specific unit
You can also upload other files or add them to the KPT package; these files will upload via the
LOAD command only if recognized by K-UPLOAD.
4.1 Upload a Kramer Package File
In the following example, a package file is used to upgrade the Kramer PL-50 machine:
1. Click the Browse button to select the package file (or, if required, a single file).
The Open window appears:
Figure 5: Select a Package File
2. Select a package file (for example, PL-50_4633_Web.kpt, downloaded from our Web site at
www.kramerelectronics.com) and click Open.
This package file includes 37 files.
Note that you can upload each of the files separately, but to avoid file version problems, it is
recommended to use the package file
The selected file appears in the Select File area (the program recognizes the file type and is
ready to upload it).
Check the “Do not check CRC” box if you want to force file upload.
Otherwise, if the same version is already running on the device, K-UPLOAD will check the
current version with the new one: if the current version is the same as the new one, it will not
upload that specific file; if the current version is different (older or newer), the new version will
be uploaded.