Appendix B Setting Sync Signal Output Termination
In some cases, it may be necessary to disable the 75-ohm termination of the
video outputs on the Cobra CAT 5 Video System units. This can be done by
opening the case of each unit and installing jumpers on the circuit board. The
settings disable/enable the 75-ohm termination on individual units. For
instance, changing a transmitter termination affects the local monitor port
only, it doesn’t affect the receivers. Conversely, changing a receiver affects
the output port of the receiver, not the transmitter. The following illustrations
show the jumper locations for the Cobra T2 unit.
75-ohm sync termination:
To enable: Both jumpers OUT (Default)
To disable: Both jumpers IN
Figure 2: Setting Sync Signal Output Termination