Owner's manual

Installing the Room Controller
9
9
Table 6: RC-63A/EU Rear Panel Features
# Feature Function
1 GND Connection Ground connection for the potentiometer
2 LVL (LEVEL) Connection Wiper of potentiometer
3 +V PIN +V connection for the potentiometer
4 FIRMWARE UPGRADE Switch For technical support use only
5 IR IN Receiver Receives IR remote commands
6 K-NET TERM Switch For line termination
7 RELAY Connections Connect to room items (such as lighting, screen settings, blinds, and
so on)
8 IR Connections Control a machine via an IR Emitter
9 RS-232 Connections Connect to the RS-232 connector on the A/V equipment or a PC or other
Serial Controller
10 PROGRAM (USB) Connector Connect to a computer for unit configuration
11 K-NET Connections On K-NET and K-NET LOOP, PIN GND is for the Ground connection
1
12
;
PIN B (-) and PIN A (+) are for RS-485, and PIN +12V is for powering the
unit
K-NET LOOP Connections
13 Grounding Screw Connect to grounding wire (optional), see section 6.4
4.3 Defining the RC-63D and RC-63DL
The Kramer RC-63D is available as a 2 Gang wall plate for the USA or a 2 Gang
wall plate for Europe. It features 6 front panel buttons designed in two groups;
one group of 2 buttons, and another group of 4 buttons. Each group can be
programmed according to the user's requirements. The:
RC-63D has the DISPLAY and SOURCES labels printed on the unit
RC-63DL is the default room controller included as part of the
SummitView™ Standard Kit Box and the SummitView™ Essentials Kit Box
and described in that user manual, and has an LCD label, letting you program
the required group label, as well as rolling text on the display
The RC-63D also includes:
A configurable digital volume control adjustment knob with five LEDs
Two relays for the simplified and centralized control of room functions (such
as lighting, closing blinds, screen settings, and so on)
An IR output, a bidirectional RS-232 port, and two K-NET ports
An IR-learner for the customized control of external sources, memorizing the
IR commands from different remote transmitters
A USB port is included for programming the RC-63D via a computer.
Figure 5, Figure 6, Table 7 and Table 8 define the RC-63D and RC-63DL.
1 The ground connection is sometimes connected to the shield of the RS-485 cable (in most applications, it is not connected)