Instruction Manual
Wiring the Rear Panel Connectors
9
6 Wiring the Rear Panel Connectors
STP cabling of 50' (15.24m)
1
in length is provided with the Kramer A/V
SummitView™ Standard Kit and the SummitView™ Essentials Kit
2
. When
required, longer STP cabling can be used when purchased for stand alone wall
plates but we recommend a maximum transmission range of up to 100'
(30.48m). Exceeding the recommended distance may result in reduced image
quality.
This section describes how to connect the rear panel for the:
US wall plate versions (see section 6.1)
European wall plate versions (see section 6.2)
6.1 Wiring the CAT 5 LINE IN / LINE OUT RJ-45 Connectors
The US versions of the SV wall plates are equipped with RJ-45 terminals.
Table 10 defines the STP CAT 5 PINOUT, using a straight pin to pin cable
with RJ-45 connectors:
Table 10: CAT 5 PINOUT (for the USA)
EIA /TIA 568B
PIN Wire Color
1 Orange / White
2 Orange
3 Green / White
4 Blue
5 Blue / White
6 Green
7 Brown / White
8 Brown
Pair 1 4 and 5
Pair 2 1 and 2
Pair 3 3 and 6
Pair 4 7 and 8
1 Plenum-rated for the SummitView™ US version; non-plenum for the SummitView™ Europe
2 Or should be purchased separately for a stand alone machine, see Table 12 for reference