Owner's manual
Flash Memory Upgrade
21
Table 14 defines the Unit number dipswitch setup:
Table 14: Machine Number Settings
Machine # DIP 1 DIP 2 DIP 3 DIP 4 Machine # DIP 1 DIP 2 DIP 3 DIP 4
1 OFF OFF OFF OFF 9 OFF OFF OFF ON
2 ON OFF OFF OFF 10 ON OFF OFF ON
3 OFF ON OFF OFF 11 OFF ON OFF ON
4 ON ON OFF OFF 12 ON ON OFF ON
5 OFF OFF ON OFF 13 OFF OFF ON ON
6 ON OFF ON OFF 14 ON OFF ON ON
7 OFF ON ON OFF 15 OFF ON ON ON
8 ON ON ON OFF 16 ON ON ON ON
6 Flash Memory Upgrade
The TP-107V
1
firmware is located in FLASH memory, which lets you
upgrade
2
to the latest Kramer firmware version in minutes! The process
involves:
Downloading from the Internet (see section 6.1)
Connecting the PC to the RS-232 port (see section 6.2)
Upgrading Firmware (see section 6.3)
6.1 Downloading from the Internet
You can download the up-to-date file
3
from the Internet. To do so:
1. Go to our Web site at www.kramerelectronics.com and download the
file: “FLIP_TP107.zip” from the Technical Support section.
2. Extract the file: “FLIP_ TP107.zip” to a folder (for example, C:\Program
Files\Kramer Flash).
3. Create a shortcut on your desktop to the file: “FLIP.EXE”.
1 This section applies also to TP-107AV, RC-108 and RC-116
2 Upgrade should be carried out by skilled technical personnel. Failure to upgrade correctly will result in the malfunction of
the machine
3 The files indicated in this section are given as an example only. File names are liable to change from time to time