User Manual

TP-410 - The SETUP DIP-switches 19
19
7 The SETUP DIP-switches
The DIP-switches on the TP-410 set the machine number of the unit.
Moving a DIP-switch down turns the switch on, moving it up turns the
switch off. Changing any DIP-switch requires that you turn the TP-410
power off and then on again.
7.1 Setting the Machine Number
To control a unit remotely via RS-232, RS-485 or the Ethernet, each unit has to be
identified via its unique machine #. DIP-switches 1, 2, 3 and 4 set the machine
number (according to the table below).
Figure 12: The Address # DIP-switches
Add. #
DIP 1
DIP 2
DIP 3
DIP 4
Add. #
DIP 1
DIP 2
DIP 3
DIP 4
1 OFF OFF OFF OFF 9 OFF OFF OFF ON
2 ON OFF OFF OFF 10 ON OFF OFF ON
3 OFF ON OFF OFF 11 OFF ON OFF ON
4 ON ON OFF OFF 12 ON ON OFF ON
5 OFF OFF ON OFF 13 OFF OFF ON ON
6 ON OFF ON OFF 14 ON OFF ON ON
7 OFF ON ON OFF 15 OFF ON ON ON
8 ON ON ON OFF
When using a single unit, set the unit to Address # 1.
Do not use the 1111 DIP-switch combination for normal operation
(see
Section 10
After setting a new machine number, turn the power off and then on again.
)
i