User manual

VP-422 - Operating the VP-422
11
5.2.2 The MAIN Menu
This section defines the MAIN MENU parameters and functions.
Parameter
Function
CONTRAST
Adjusts the contrast
BRIGHTNESS
Adjusts the brightness
FINETUNE
Adjusts the other ProcAmp parameters: PHASE, HUE, SATURATION
and SHARPNESS (see Section 5.2.3)
COLOR
Adjusts the color of the display RED, GREEN, BLUE
SIZE
Select the size of the display: FULL, OVERSCAN, UNDER 1, UNDER
2, LETTER BOX, PANSCAN and BEST FIT
OUTPUT
Sets the output resolution (see Section 5.2.4)
OSD
Adjusts the parameters of the on-screen display (see Section 5.2.5)
FACTORY RESET
Resets the device to its factory default parameters and automatically
senses the input and output devices
The COMPONENT OUT LED lights blue
INFORMATION
Displays the input and output resolutions and the software version
Note that upon any change in the resolution, the input/output
resolutions also appear on the display for a few seconds
AUTO SYNC OFF
ON/OFF (default is off)
Turn the auto sync ON/OFF. When ON, a short period (about 2
minutes) after not detecting a valid video signal on the selected input,
the unit will disable the H and V syncs on the analog outputs until a
valid input is again detected or any keypad is pressed
FREEZE
FREEZE ONLY / FREEZE + MUTE / MUTE ONLY
EXIT
Select to exit the OSD
5.2.3 FINETUNE Menu
This section defines the “FINETUNE” Submenu
Input Signal
Parameter
Function
HDMI
COLOR FILTER
Set to ON to enable color filtering
DROP LINES
Set it to ON to eliminate the green line (default
is OFF)
With some sources (mostly Apple devices) a green
line sometimes appears at the bottom of the
display. By factory default this option is set to OFF.
EXIT
Select to exit to the Main Menu