Owner manual
6 VP-4x4K - Overview
# Feature Function
15 + Button Press to increase the numerical value
16 STATUS 7-segment
Display
Displays the selected input switched to the output
(marked above each input)
Also displays the number of IN and OUT ports, the
firmware version number, the MACHINE # and the audio
gain level. Refer to Section
6.1
17 INPUT 15-pin HD
Connectors
Connect to the video sources (from 1 to 4)
18 OUTPUT 15-pin HD
Connectors
Connect to the acceptors (from 1 to 4)
19 AUDIO INPUTS 3.5mm
Mini Plug Connectors
Connect to the unbalanced stereo audio sources (from
1 to 4)
20 AUDIO OUTPUTS
Terminal block connectors
Connect to the balanced stereo audio acceptors (from
1 to 4)
21 PROGRAM Button Not used (for technical staff use only)
22 Ethernet Connector Connects to the PC or other Serial Controller through
computer networking
23 Factory Reset Button Press to reset to the factory default definitions:
IP number − 192.168.1.39
Mask – 255.255.0.0
Gateway – 0.0.0.0
UDP port – 50000
TCP port – 5000
Protocol 3000 commands
All 8 Presets deleted
All audio channels set to 0dB
Machine name – the last four digits of the machine's
serial number
DHCP disabled
Turn the POWER switch OFF and then ON again while
pressing the Factory Reset button. The unit will power up
and load its memory with the factory default definitions
24 RS-485 TERM DIP-switch DIP 1 is for RS-485 Termination, DIP 2 is not used
25 RS-485 Terminal Block
Port
Pins B (-) and A (+) are for RS-485; Pin G (Ground)
may be connected to the shield of the cable if desired
26 RS-232 9-pin D-sub
Connector
Connects to the PC or the Remote Controller
27 Power Connector with
Fuse
AC connector enabling power supply to the unit