Owner manual
36 VP-4x4K - Communication Parameters
9 Communication Parameters
VP-4x4K communication parameters are listed here.
EDID
EDID data is passed between Input 1 and Output 1
RS-232
Protocol 2000 Protocol 3000 (Default)
Baud Rate: 9600 Baud Rate: 115,200
Data Bits: 8 Data Bits: 8
Stop Bits: 1 Stop Bits: 1
Parity: None Parity: None
Command Format: HEX Command
Format:
ASCII
Example (Output 1 to
Input 1):
0x01, 0x81, 0x81,
0x81
Example (Output
1 to Input 1):
#AV 1>1<CR>
Switching Protocol
P2000 -> P3000 P3000 -> P2000
Command: 0x38, 0x80, 0x83,
0x81
Command: #P2000<CR>
Front Panel: Press and hold
Output 1 and
Output 3
simultaneously
Front Panel: Press and hold
Output 1 and
Output 2
simultaneously
Ethernet
Default Settings Reset Settings
IP Address: 192.168.1.39 Power cycle the unit while holding in the Factory Reset button,
located on the rear panel of the unit.
TCP Port #: 5000
UDP Port #: 50000