User manual

VP-4x4K - Connecting the VP-4x4K 11
5.4 Cascading Machines
You can cascade up to 16 VP-4x4K units with control from a PC or serial
controller.
To cascade 16 individual VP-4x4K units via RS-485, as illustrated in the example
in
Figure 5, do the following:
1. Connect the sources and acceptors (see Section
5.1).
2. Connect the RS-232 port of the first VP-4x4K unit to a PC.
3. Connect the RS-485 terminal block port on the first VP-4x4K unit to the
RS-485 port on the second VP-4x4K unit and so on, connecting all the
RS-485 ports.
4. Set the first VP-4x4K unit as Machine # 1 and the following VP-4x4K units
as Machine # 2 to Machine # 16 (see Section
6.4).
5. On the first and last VP-4x4K units, set the RS-485 TERM DIP-switch to ON,
terminating the RS-485 line at 120 (see Section
5.6), and set this DIP-
switch to OFF on the other VP-4x4K units.