Specifications
36
Like the H/V Start adjustment, you must use an oscilloscope
when making these adjustments so that you know exactly how
many milliseconds or microseconds of pulse width you have
created. The numbers shown are relative numbers and not an
actual time measurement.
Sync can be either negative polarity or positive polarity. To further complicate
things, it is possible that you may want to make the Horizontal Sync polarity
different from the Vertical Polarity. This control allows you to make that change.
You have four possible selections:
+H+V
-H+V
+H-V
-H-V
7.8 Items Associated with the
The final Sub Menu is for adjustments of System parameters. The “System” in this
case means the unit’s functions that are generally unrelated to individual inputs,
outputs or any of the various production features.
System group
This screen is an informational screen. Should you require technical assistance
with your unit, the technical support personnel may request that you read the
contents of this screen to them during the support call.
The first section, “SW”, is the version of the software that is installed on your unit.
You can update software via the User Support web site (procedure to be described
later in this manual) and the updates are currently free of charge. “PT” refers to
Product Type and “BT” means Board Type. Both of these are hardware
designators and cannot be changed by the user however both designators are
important to support personnel.
This is an information page showing when the currently installed software was
released. The information is useful to the user as he or she compares the date to
the website information describing the current software release.
800 x 600 60 Hz
Sync polarity [+H+V]
System
SW: 16, PT: 12, BT: 13
System
SW date: 2006-7-11