User manual

VP-725N - VP-725N Communication Protocol 53
Communication Protocol of the VP-725N
Control Type
Function Parameter Description
Set
Get
0 1 113
480~1200
<= (VT-16)
Advance Input Mode: VA
0 1 114
0: Negative polarity
1: Positive polarity
Advance Input Mode: VP
0 1 115 25 < OCLK < 165 Advance Input Mode: OCLK(Integer)
0 1 116 25 < OCLK < 165 Advance Input Mode: OCLK(Decimal)
0 1 117
0: Off
1: On
Advance Input Mode: Enable
0 - 118 N/A Advance Input Mode: Save
0
1
119
512~3071
Advance Output Mode: HT
0
1
120
32~(HS-48)
Advance Output Mode: HW
0
1
121
80~(HT-HA-12)
Advance Output Mode: HS
0 1 122
640~1920
<= (HT-92)
Advance Output Mode: HA
0 1 123
0: Negative polarity
1: Positive polarity
Advance Output Mode: HP
0
1
124
384~2047
Advance Output Mode: VT
0
1
125
2~(HS-13)
Advance Output Mode: VW
0
1
126
15~(VT-VA-1)
Advance Output Mode: VS
0 1 127
480~1200
<= (VT-16)
Advance Output Mode: VA
0 1 128
0: Negative polarity
1: Positive polarity
Advance Output Mode: VP
0
1
129
25 < OCLK < 165
Advance Output Mode: OCLK(Integer)
0
1
130
25 < OCLK < 165
Advance Output Mode: OCLK(Decimal)
0 - 131 N/A Advance Output Mode: Save
0 - 132 N/A Advance Output Mode: Set Current
0 1 135
0: Follow Output
1: Follow Input
HDCP Setting
0 1 136
0: Custom1
1: Custom2
2: Custom3
3: Custom4
Advance Input Mode: Custom Input
0 1 137
0: Custom1
1: Custom2
2: Custom3
3: Custom4
Advance Output Mode: Custom Output
0 1 138
0: Off
1: On
Overscan
0 1 139
0: Seamless
1: Fast
Switching Mode
0 1 140
0: Manual
1: Auto
Auto Image Mode
0
-
141
N/A
Slideshow Start
0
-
142
N/A
Slideshow Stop
0 - 143 N/A Slideshow Pause
0 - 144 N/A Slideshow Next
0
-
145
N/A
Slideshow Previous
0 1 146
0: Min
1: Low
2: Mid
3: Long
4: Max
Slideshow