User Manual

Flash Memory Upgrade
11
6. The Open File window opens. Select the correct HEX file that contains the
updated version of the firmware for VS-202YC (for example,
202YCM_V1p2.hex) and click Open.
7. Press the keyboard shortcut key F3 (or select the Communication / RS232
command from the Settings menu, or press the keys: Alt SCR).
The RS232” window appears. Change the COM port according to the
configuration of your computer and select the 9600 baud rate:
Figure 12: RS-232 Window
8. Click Connect.
In theAtmel Flip window, in the Operations Flow column, the Run button
is active, and the name of the chip appears as the name of the third column:
AT89C51RD2.
Verify that in the Buffer Information column, theHEX File: VS202YC.hex
appears.
A
VS202YC.hex
Figure 13: Atmel – Flip Window (Connected)