Owner's manual

VS-41HDCP - Kramer Protocol
25
Instruction Codes for Protocol 3000
Command Name
Short Cmd
Command Type
Permission
#
Common-mandatory
End User
Protocol handshaking
Syntax
#
Response
~nn@OK␍␊
Parameters
Notes
Use to validate protocol 3000 connection and to get machine number.
Command Name
Short Cmd
Command Type
Permission
BUILD-DATE
Common-mandatory
End User
Read device build date
Syntax
#BUILD-DATE?
Response
~nn@BUILD-DATEdate time␍␊
Parameters
date Format: YYYY/MM/DD where YYYY = Year. MM = Month. DD = Day.
time Format: hh:mm:ss where hh = hours. mm = minutes. ss = seconds.
Command Name
Short Cmd
Command Type
Permission
MODEL?
Common-mandatory
End User
Read device model
Syntax
#MODEL?
Response
~nn @MODELmodel_name␍␊
Parameters
model_name String of printable ASCII chars (up to 19 chars).
Command Name
Short Cmd
Command Type
Permission
SN?
Common-mandatory
End User
Reset device serial number
Syntax
#SN?
Response
~nn @SNserial_number␍␊
Parameters
serial_number 11 decimal digits. Assign by Kramer factory.
Notes