User manual

VS-44HDCP - Protocol 3000
33
Command - LDEDID
Command Type - System
Command Name
Permission
Transparency
Set:
LDEDID
End User
Public
Get:
-
-
-
Description
Syntax
Set:
Write EDID data from external
application to device
Multi-step syntax (see following steps)
Get:
None
None
Communication Steps (Command and Response)
Step 1: #LDEDID eeprom_id, size
Response 1: ~nn@LDEDID eeprom_id, size READY␍␊ or
~nn@LDEDIDERRnn␍␊
Step 2: If ready was received, send EDID_DATA
Response 2: ~nn@LDEDID eeprom_id, size OK␍␊
Parameters
eeprom_id EEPROM to put the EDID into
size Size of EDID that will send.
EDID_DATA - HEX or KFW file in protocol packets (see Section 11.3.1)
Response Triggers
Response is sent to the com port from which the Set (before execution)
Notes
When the unit receives the LDEDID command it replies with READY and enters the special EDID
packet wait mode. In this mode the unit can receive only packets and not regular protocol commands.
If the unit does not receive correct packets for 30 seconds or is interrupted for more than 30 seconds
before receiving all packets, it sends timeout error ~nn@LDEDIDERR01␍␊ and returns to the
regular protocol mode. If the unit received data that is not a correct packet, it sends the corresponding
error and returns to the regular protocol mode.
See Protocol Packet reference in Section 11.3.1