User manual
Your VS-48HDxl 3G HD/SD SDI 4x8 Matrix Switcher
7
Table 2: Rear Panel VS-48HDxl 3G HD/SD SDI 4x8 Matrix Switcher
# Feature Function
12 GENLOCK BNC Connector Connect to the Genlock source
13
TERM 75
Button Press to terminate the Genlock source (75) or release for looping
1
14 LOOP BNC Connector Connect to the GENLOCK connector of the next unit in the line
15 DUAL LINK INPUT BNC
Connectors
In the dual-link mode, connect the source to inputs 1 and 2 and/or inputs 3
and 4 (DUAL LINK 1 and/or DUAL LINK 2)
16 INPUT BNC Connectors Connect to the serial digital video sources (from 1 to 4)
17 DUAL LINK OUTPUT BNC
Connectors
In the dual-link mode, connect the acceptors to outputs 1 and 2 and/or
outputs 3 and 4 and/or outputs 5 and 6 and/or outputs 7 and 8 (DUAL
LINK 1 and/or DUAL LINK 2 and/or DUAL LINK 3 and/or DUAL LINK 4,
respectively)
18 OUTPUT BNC Connectors Connect to the serial digital video acceptors (from 1 to 8)
19 RS-232 9-pin D-sub Port Connects to the PC or the Remote Controller
20 RESET Button Press to reset Ethernet to factory default definitions
2
:
IP number 192.168.1.39
Mask – 255.255.255.0
Gateway – 192.168.1.1
21 ETHERNET RJ-45 Connector
Connects to the PC or other Serial Controller through computer networking
22 REMOTE INPUT Terminal
Block Connectors
Connect to dry contact switches
3
(from 1 to 4)
23 REMOTE OUTPUT
Terminal Block Connectors
Connect to dry contact switches (from 1 to 8)
24 RS-485 Detachable
Terminal Block Port
Pin G is for the Ground connection
4
; pins B (-) and A (+) are for RS-485
25 REMOTE IR Opening
5
Connects to an external IR receiver unit for controlling the machine via an
IR remote controller (instead of using the front panel IR receiver)
6
26 SETUP Dipswitches Dipswitches for setup of the unit
27 Power Connector with Fuse AC connector enabling power supply to the unit
1 Push in to terminate the input. Release when the input extends to another unit
2 First disconnect the power cord and then connect it again while pressing the ETH Factory Reset button. The unit will power
up and load its memory with the factory default definitions
3 See section 6.9
4 The ground connection is sometimes connected to the shield of the RS-485 cable. In most applications, the ground is not
connected
5 Covered by a cap. The 3.5mm connector at the end of the internal IR connection cable fits through this opening
6 Optional. Can be used instead of the front panel (built-in) IR receiver to remotely control the machine (only if the internal
IR connection cable has been installed)