Spec Sheet

TECHNICAL SPECIFICATIONS
CONSTRUCTION
Conductor: 4 pairs of 23AWG solid bare copper
Insulation: Polyolefin (PO); blue & white/blue stripe, orange & white/orange stripe,
green & white/green stripe, brown & white/brown stripe
Twist: Left−hand
Assembly: Left hand direction
Rip Shield: Mylar tape
Drain Wire: 24AWG solid tinned copper
Shield: Al Mylar tape, 100% coverage and mylar side facing out
Jacket: Low smoke zero halogen (LSZH), green (Pantone 7732C)
Filler:
Polyolefin (PO)
DIAMETERS
Jacket: Diameter: 7.2 ±0.2mm; thickness: 0.45 ±0.05mm
Insulation: Blue & white/blue stripe: 1.08 ± 0.02mm
Orange & white/orange stripe: 1.05 ± 0.02mm
Green & white/green stripe: 1.08 ± 0.02mm
Brown & white/brown stripe: 1.05 ± 0.02mm
ELECTRICAL
Temperature & Voltage Rating: 60°C @300V
Spark Test: 2.5kV DC
AC Leakage Current: ≤10mA (1.5kV AC) through overall jacket
Conductor DC Resistance: ≤9.38Ω /100m
Resistance Unbalance: ≤5%
Dielectric Strength: 1.5kV AC for 2sec
Insulation Resistance: ≥5000MΩ /m
Mutual Capacitance: ≤5.6nF /100m
Capacitance Unbalance: ≤330pF /100m pair−to−ground
Characteristic Impedance: 100±15Ω @1~100MHz
Coupling Attenuation: ≤55dB @30MHz, ≤47dB @250MHz
USAGE AND
ENVIRONMENTAL
Cable Cold Bend: −20°C for 4hr
Insulation Tensile Strength: 2400 PSI min. (1.69kg/m^2)
NVP 69%
Temperature Range: Storage & shipping: −20°C to 60°C; installation: 0°C to 60°C;
operation: −20°C to 60°C
Minimum Bending Radius: ≥4 times of overall diameter
Maximum Pulling Tension: ≤110N
REGULATORY
PERFORMANCE
ANSI/TIA-568-C.2 (2009): Balanced Twisted−Pair Telecommunications Cabling and
Components Standards