User's Manual
Table Of Contents
- Introduction
- Defining the PA-240Z 240W Power Amplifier
- Connecting the PA-240Z
- Operating the PA-240Z
- Using the Embedded Web Pages
- Technical Specifications
- Protocol 3000
Kramer Electronics Ltd.
PA-120Z, PA-240Z – Protocol 3000
34
MODEL
Functions
Permission
Transparency
Set:
-
-
-
Get:
MODEL?
End User
Public
Description
Syntax
Set:
-
-
Get:
Get device model
#MODEL?CR
Response
~nn@MODELSPmodel_nameCR LF
Parameters
model_name – String of up to 16 printable ASCII chars
Notes
This command identifies equipment connected to Step-in master products and notifies of identity changes
to the connected equipment. The Matrix saves this data in memory to answer REMOTE-INFO requests
K-Config Example
“#MODEL?”,0x0D
PROT-VER
Functions
Permission
Transparency
Set:
-
-
-
Get:
PROT-VER?
End User
Public
Description
Syntax
Set:
-
-
Get:
Get device protocol version
#PROT-VER?CR
Response
~nn@PROT-VERSP3000:versionCR LF
Parameters
version - XX.XX where X is a decimal digit
K-Config Example
“#PROT-VER?”,0x0D
RESET
Functions
Permission
Transparency
Set:
RESET
Administrator
Public
Get:
-
-
-
Description
Syntax
Set:
Reset device
#RESETCR
Get:
-
-
Response
~nn@RESETSPOKCR LF
Notes
To avoid locking the port due to a USB bug in Windows, disconnect USB connections immediately after
running this command. If the port was locked, disconnect and reconnect the cable to reopen the port.
K-Config Example
“#RESET”,0x0D