User's Manual

Table Of Contents
Kramer Electronics Ltd.
PA-120Z, PA-240Z Protocol 3000
39
AUD-LVL
Functions
Permission
Transparency
Set:
AUD-LVL
End User
Public
Get:
AUD-LVL?
End User
Public
Description
Syntax
Set:
Set volume level
#AUD-LVLSPstage,channel,volume,mutebehaviorCR
Get:
Get volume level
#AUD-LVL?SPstage,channel
Response
~nn@AUD-LVLSP stage,channel,volumeCR LF
Parameters
stage 1 (For output processing)
channel 1 (Speaker Output), 2 (Line Level Output)
volume volume level -80db to 10dB
mutebehavior optional, 1 (changing the volume does not affect the mute state)
K-Config Example
Set the speaker output audio level t0 -50dB:
“#AUD-LVL 1,1,-50”,0x0D
AUD-MIX
Functions
Permission
Transparency
Set:
AUD-MIX
End User
Public
Get:
AUD-MIX?
End User
Public
Description
Syntax
Set:
Set mixer level
#AUD-MIXSPchannel,knob,levelCR
Get:
Get mixer level
#AUD-MIX?SPchannel,knobCR
Response
~nn@AUD-MIXSPchannel,knob,levelCR LF
Parameters
channel 1 (Speaker Output), 2 (Line Level Output)
knob mixer knob number: 1 (Input 1), 2 (Input 2)
level mixer level: -80 to 10dB
K-Config Example
Set the input mixing level of input 2 on the speaker output to -48dB:
“#AUD-MIX 1,2,-48”,0x0D