User's Manual

Table Of Contents
Kramer Electronics Ltd.
PA-120Z, PA-240Z Protocol 3000
41
AUD-STANDBY
Functions
Permission
Transparency
Set:
AUD-STANDBY
End User
Public
Get
AUD-STANDBY?
End User
Public
Description
Syntax
Set:
Set standby mode
#AUD-STANDBYSPStandbyMode,TimeDelayCR
Get:
Get standby mode state
#AUD-STANDBY?CR
Response
~nn@AUD-STANDBYSPStandbyMode,TimeDelayCR LF
Parameters
StandbyMode 0 (Off), 1 (Delayed, auto mode), 2 (Standby mode)
TimeDelay 5, 10, or 15 (time delay [min] to standby mode)
Notes
Active only in auto mode
K-Config Example
Set the standby delay time to 10 minutes:
“#AUD-STANDBY 1,10”,0x0D
BALANCE
Functions
Permission
Transparency
Set:
BALANCE
End User
Public
Get:
BALANCE?
End User
Public
Description
Syntax
Set:
Set balance level
#BALANCESPchannel,balancelevelCR
Get:
Get balance level
#BALANCE?SPchannelCR
Response
~nn@BALANCESPchannel,balance_levelCR LF
Parameters
channel 1 (Speaker output), 2 (Line level output)
balancelevel -15 to +15 (audio parameter in Kramer units, minus sign precedes negative values)
++ (increase current value)
-- (decrease current value)
K-Config Example
Set the speaker output balance to +12:
“#BALANCE 1,12”,0x0D