User's Manual

Table Of Contents
Kramer Electronics Ltd.
PA-120Z, PA-240Z Protocol 3000
42
EQ-FREQ
Functions
Permission
Transparency
Set:
EQ-FREQ
End User
Public
Get
EQ-FREQ?
End User
Public
Description
Syntax
Set:
Set equalizer frequency
#EQ-FREQSPStage,Channel,EqType,EqFreqCR
Get:
Get equalizer frequency
#EQ-FREQ?SPStage,Channel,EqTypeCR
Response
~nn@EQ-FREQSPStage,Channel,EqType,EqFreqCR LF
Parameters
Stage 1 (Output)
Channel 1 (Speaker output), 2 (Line Level Output)
EqType 0 (Bass), 1 (Middle), 2 (Treble)
EqFreq 0 (T: 10kHz, M: 500Hz, B: 60Hz), 1 (T: 12.5kHz, M: 1kHz, B: 80Hz), 2 (T: 15kHz, M: 1.5kHz, B:
500Hz), 3 (T: 17.5kHz, M: 2.5kHz, B: 200Hz)
Notes
T=Treble, M=Middle, B=Bass
K-Config Example
Set speaker output equalizer frequency on the bass to 200Hz:
“#EQ-FREQ 1,1,0,3”,0x0D
EQ-LVL
Functions
Permission
Transparency
Set:
EQ-LVL
End User
Public
Get:
EQ-LVL?
End User
Public
Description
Syntax
Set:
Set equalization level
#EQ-LVLSPStage,Channel,EqType,LevelCR
Get :
Get equalization level
#EQ-LVL?SPStage,Channel,EqTypeCR
Response
~nn@EQ-LVLSPtage,Channel,EqType,LevelCR LF
Parameters
Stage 1 (Output processing)
Channel 1 (Speaker output), 2 (Line level output)
EqType 0 (Bass), 1 (Middle), 2 (Treble)
Level equalizer level
K-Config Example
Set Bass EQ level of the speaker output to 12:
“#EQ-LVL 1,1,0,12”,0x0D