Operation Manual
16
Small repairs - Do it yourself!
The nozzle is blocked !
No water but the gauge shows full pressure.
Rinse the hose
through first.
You should now have
a powerful stream of
water,
remove the lance and
clean the nozzle.
Using the flat spray lance
you only have to clean the
front nozzle.
Straighten a paper
clip and clean the
nozzle.
Check visually whether the
nozzle is clean.
Now it works
as well as
before.
but if you only
get a few drops
of water from
the lance,
Clean out the
nozzle
Clean out the
nozzle
Remove deep
lying dirt