Inspections
Accident prevention
The machine must be inspected according to the “Guidelines for Liquid Spray
Devices” at least once every 12 months by a qualified person, to ensure that
continued safe operation is guarateed.
The results of the inspection are to be recorded in writing. (see pages 48-49)
General rules
The machine is designed for accidents to be impossible if used correctly.
The operator is to be notified of the risk of injury from hot machine parts and the
high pressure water jet. The “Guidelines for Liquid Spray Devices” must be
complied with. (see pages 16 - 17).
Check the oil level at the oil dip stick prior to each use (see also page 11).
(Ensure horizontal position!)
Oil change:
The first oil change should be carried out
after approximately 50 operating hours,
then every year or after 1000 operating
hours. If the oil turns grey or white, you
must change the oil of your high pressure
pump in any case.
Place the device over a collection resevoir
and open the oil discharge screw at the
bottom.
Ensure a horizontal position to drain the
oil completely. The oil is to be caught in
the reservoir and disposed of in an
approved manner.
New oil: 0,8 l
Motor oil: Castrol 10 W-60 SAE halfsynthetic oil
Oil discharge screw