GB Operating manual High-pressure cleaner WS 700 TS 230V~1/60Hz WS 1200 TS 230V~3/60Hz WS 1200 TS 440V~3/60Hz www.kraenzle.
Operating manual DE High-pressure cleaner WS 700 TS 230V~1/60Hz WS 1200 TS 230V~3/60Hz WS 1200 TS 440V~3/60Hz Operating manual! Read and conform safety instructions before use! Keep instructions in a safe place for later use and pass them on to any future user.
Contents Dear customer: We would like to congratulate you on the purchase of your new high pressure cleaner and thank you for your confidence in our products! Your choice has fallen on an absolute quality product! Kränzle high pressure cleaners are characterized by their convenient and compact design as well as their high suitability for everyday use.
Explanatory symbols Explanatory symbols used in the operating manual Failure to observe this note may entail environmental damage. Note on the use of the high pressure cleaner that failure to adhere to the instructions may cause excessive wear or total breakdown of the WS-series. Warning! Failure to observe this note may result in serious injuries! Auf dem Hochdruckreiniger verwendete Bildzeichen In case of improper use, the high pressure jets can be very dangerous.
Safety notes User operating the high pressure cleaner should wear the necessary protective clothing, i.e. waterproof clothing, rubber boots, safety goggles, headwear etc. It is prohibited to use the high pressure cleaner in close vicinity to people lacking suitable protective clothing.
Safety notes - This is prohibited! When using high pressure water for cleaning, make sure that there is a clearly noticeable recoil effect on the lance. Therefore ensure a firm footing (see technical data).
Safety notes - This is prohibited! Never direct the high pressure jet at power sockets or any other electrical installations! Within the working area, all live parts are to be protected from both water jet and spray mist.
Safety notes - This is prohibited! Never direct the high pressure jet at people or animals! Never direct the high pressure jet at yourself or other persons, not even to clean clothing or shoes. Only use a power supply cable in perfect working order! Do not damage or improperly repair the power cable (tearing, squeezing, running over, ...).
Description of high pressure cleaner Design: The WS 700 TS/ WS 1200 TS is a high-pressure cleaner capable of being applied both standing on the floor or hanging on the wall. Please see construction scheme for more details. 1 4 7 5 3 8 1. Handles 2. Pump head made of special brass 3. Holder for lance (only applicable in case of wall mounting) 4. Large stainless steel pressure gauge 5. On/Off switch with motor protection 10 6. Pedestals 7. Eyelets for wall mounting 8.
Description of high pressure cleaner This is what you have purchased: 1. Kränzle high pressure cleaner WS 700 TS / WS 1200 TS 2. Trigger gun with safety catch, short design with quick release coupling 3. Stainless steel lance with flat jet nozzle and quick release coupling 4. Operating manual spare parts list 5. high pressure hose 6.
General rules Range of application Use high pressure cleaner for cleaning purposes only using high pressure jet with or without cleaning detergent. Environmental, refuse disposal and water protection regulations must be observed! Inspections The high pressure cleaner must be inspected according to the “Guidelines for Liquid Spray Devices” at least once every 12 months by a qualified person, to ensure that continued safe operation is guaranteed.
General rules Oil change The first oil change should be carried out after approximately 50 operating hours, then every year or after 250 operating hours. If the oil turns grey or white, you must change the oil. In case of exchanging oil being required, the oil drain screw must be opened above a container and the high pressure cleaner be emptied. The oil is to be caught in the reservoir and disposed of in an approved manner. New oil: 1.0 l Kränzle Gear Oil (Item no. 40.
Functional details Please note: Lack of water Lack of water occurs more often than you probably believe. The more powerful a high pressure cleaner is the greater is the danger that a lack of water occurs. If there is only an insufficient amount of water available, cavitation (water-gas mixture) arises inside the high pressure pump, which is normally noticed too late or even not at all. The high pressure pump will be destroyed.
Functional details Insufficient quantity of electricity If there are too many collectors in your proximity connected to the network at the same time, the available voltage and the current intensity may decline. Consequently the motor of the high pressure cleaner does not start or even blows. The power supply may also be insufficient if the power supply cable is too long or too thin. If extension cables are too long, this may lead to a voltage drop causing malfunctions or start-up difficulties.
Functional details Water and cleaning system Water must be supplied to the high pressure pump under pressure or directly sucked in out of a pressureless container. The water is then forced under pressure by the high pressure pump to the lance. The high pressure jet is formed by the nozzle at the end of the lance.
Functional details Pressure control valve - safety valve The pressure control valve - safety valve protects the high pressure cleaner from a build up of excess pressure, and is designed not to permit an excess pressure to be selected for operation. The limit nut on the handle is sealed with a spray coating. The operating pressure and spray rate can be steplessly adjusted by turning the handle. Replacements, repairs, new adjustments and sealing should only be performed by qualified persons.
Functional details Safety shutdown If the high-pressure cleaner is accidentally not turned off after use or the safety trigger gun is not used for 20 minutes, the high-pressure cleaner automatically changes into safety state by deactivation. By operating the main switch once more, the high-pressure cleaner is activated again.
Putting into operation The high-pressure cleaner may be carried by two persons. Please note the weight of the high-pressure cleaner (refer to technical data). When setting down the high-pressure cleaner please provide for a safe stand. The WS-series may be applied both as a standing device as well as mounted on the wall. When setting down the high-pressure cleaner please provide for a safe stand. Wall mounting Fasten the holders for the lances using a Phillips head screwdriver and the screws enclosed.
Putting into operation Neither set up or operate the WS-series in rooms where there is a risk of fire or explosion nor put it into puddles. Do not use the high pressure cleaner under water. If, none the less, the high pressure cleaner is operated in a hazardous area, the applicable safety regulations are to be observed. 20 1. Unwind high pressure hose straight and without nooses. (When using high pressure hose extensions take care that the max. length of 20 m is not exceeded!) 2.
Putting into operation 4. First pull back the retaining sleeve of the safety trigger gun, then insert lance into the plug coupling sconnection of the safety trigger gun. 5. After insertion of the lance, release retaining sleeve and make sure that the lance is in a secure position. Grease quick release nipple regularly using acid-free grease. Prior to insertion, check plug coupling connection of lance for cleanliness (sand, dirt ..) and use clear water to clean, if necessary.
Putting into operation 10. If using a water inlet filter check it for cleanliness prior to each startup. Manually unscrew filter bowl, remove sieve and thoroughly rinse and clean with the rest of the parts in clear water. Check the water inlet sieve for damage. Do not operate the high pressure cleaner without or with a damaged filter. 11. Connect the water hose to water inlet sieve.
Putting into operation 13. Connect to circuit (see technical data). Do not touch the mains plug or any live parts with wet or moist hands. 14. Switch on high pressure cleaner with opened safety trigger gun. Bleeding of the high pressure cleaner: Pull and release trigger of safety trigger gun several times. Start cleaning task. 15. When using the turbokiller lance (optional) make sure that lance points downward when starting. 16. Adjust operating pressureinfinitely using the rotary handle.
Direct suction Direct water extraction Due to the suction capacity of its high pressure pump (up to 2.5 m suction height, max. hose length 3 m) this high pressure cleaner can suck in water for cleaning purposes from separate containers or ponds. 1. Mount suction hose with suction filter (Item.-no. 15.038 3). 2. Put filled suction hose into the waterfilled container and start the cleaning job.
Taking out of operation 1. Switch off the high pressure cleaner 2. Cut off the water supply 3. Open the safety trigger gun catch briefly until the pressure is released 4. Apply safety catch on the trigger gun 5. Remove high pressure hose and safety trigger gun 6. Emptying high pressure pump: Hold high pressure hose and switch motor on until water jet stops escaping at the outlet. 7. Pull the plug from the socket 8. Clean high pressure hose and wind up without loops 9.
Small repairs - do it yourself Problem No water from nozzle although the high pressure cleaner is running. The stainless steel pressure gauge shows full pressure. Cause Most likely the nozzle is blocked. The stainless steel pressure gauge shows full pressure, but from the nozzle comes only little water or no water at all. (Inside the stainless steel pressure gauge is no water but a filling with glycol to damp the vibration of the pointer.) Proceeding: Switch off the high pressure cleaner.
Small repairs - do it yourself Problem Irregular jet from nozzle. The stainless steel pressure gauge shows low pressure. Cause Most likely the valves are soiled or sticky. The stainless steel pressure gauge shows low pressure despite fully turned up pressure regulation. The water from the lance comes in squirts. The high pressure hose vibrates. (Inside the stainless steel pressure gauge is no water but a filling with glycol to damp the vibration of the pointer.
Small repairs - do it yourself Problem After closing the safety trigger gun the high pressure cleaner keeps switching on and off. The stainless steel pressure gauge continuously displays full pressure. Possible cause No. 1 Leckage. Having closed the trigger gun with safety catch, the high pressure cleaner must shut down and the stainless steel pressure gauge must show „0“ bar.
Small repairs - do it yourself Problem After closing the safety trigger gun the high pressure cleaner keeps switching on and off. The stainless steel pressure gauge continuously displays full pressure. Possible cause No. 2 The non-return valve is defective. Proceeding: Switch off the high pressure cleaner and pull plug from socket. Stop water supply. Unscrew pump outlet. Remove check body and check O-Ring for soiling or damage. Also check seal seat inside pump housing for soiling or damage.
Kränzle accessories Double lance with insulated ISO handle Low pressure nozzle D3035 as standard 660 mm 1000 mm Item no. 12.131 1 Item no. 12.131 Floor washer Round Cleaner (stainless steel) from stainless steel various executions Nozzle system 055 ∅ 300 mm Item no. 41.105 ∅ 420 mm Item no. 41.106 ∅ 520 mm Item no. 41.107 Underbody lance Stainless steel pipe 1000 mm extension Nozzle system 4007 Item no. 41.
Kränzle accessories Adapter for accessories with screw connections with quick release nipple For item no. 12.440 (fig. left) 400 mm extension with grip plates Item no. 12.440 (fig. left) Item no. 12.441 (fig. right) Suction hose with suction filter with return valve hose length 3 m Item no. 15.038 3 Rotating washing brush 400 mm Stainless steel extension Brush head ∅ 180 mm Nozzle size 3.2 mm * in combination with adapter only Item no. 41.
EC declaration of conformity We here by declare that the design of Kränzle WS 700 TS (230V~1/60Hz) the high pressure cleaner: Kränzle WS 1200 TS (230V~3/60Hz) Kränzle WS 1200 TS (440V~3/60Hz) Nominal flow: Kränzle WS 700 TS (230V~1/60Hz): 3.3 Gpm Kränzle WS 1200 TS (230V~3/60Hz): 5.0 Gpm Kränzle WS 1200 TS (440V~3/60Hz): 5.0 Gpm technical specifications Fa. Josef Kränzle GmbH & Co. KG available from: Manfred Bauer Rudolf-Diesel-Str.
Warranty Warranty Our warranty obligation is understood to exclusively cover material and manufacturing defects, wear is not covered by warranty. The high pressure cleaner is to be operated in conformity with this Operating manual. The operating manual is deemed to be part of the warranty provisions. This warranty shall only apply on condition of proper use of original-Kränzle component parts and original-Kränzle replacement parts.
Inspection reports High pressure cleaners for industrial use have to be checked by an expert every 12 months! Inspection report on annually carried out Labour Safety Inspection (UVV) according to the Guidelines for Liquid Spray Equipment. (This inspection sheet serves as proof for the completion of the retest and must be kept carefully!) Kränzle-test seals: Item no.: UVV200106 Owner: .................................................................................. Address: ................................
Inspection reports High pressure cleaners for industrial use have to be checked by an expert every 12 months! Inspection report on annually carried out Labour Safety Inspection (UVV) according to the Guidelines for Liquid Spray Equipment. (This inspection sheet serves as proof for the completion of the retest and must be kept carefully!) Kränzle-test seals: Item no.: UVV200106 Owner: .................................................................................. Address: ................................
sales@kraenzle.com © Kränzle 14.02.2018 / Subjecto to technical modifications and errors. Josef Kränzle GmbH & Co. KG Rudolf-Diesel-Straße 20 89257 Illertissen (Germany) Made in Germany www.kraenzle.