Installation Guide

9
Trouble - Shooting
If you have followed the instructions carefully and your faucet still does not work
properly, take the following corrective steps:
PROBLEM CAUSE ACTION
Leakage under the
handle
Locking nut (7) has
come loose
Loosen set screw (2)
with hex wrench (17).
Remove metal handle
(1), cartridge cover (3),
cartridge sleeve (4),
metal o-ring (5) & rubber
washer (6). Tighten
locking nut (7) with
wrench
Aerator drips or has
inconsistent water flow
pattern
Aerator (14) may be
dirty or not seated
properly
Unscrew aerator (14)
with aerator key (15).
Remove aerator (14)
and clean out debris
Water will not shut off
completely
Cartridge(8) may need
to be adjusted or
replaced
Loosen set screw (2)
with hex wrench (17).
Remove metal handle
(1), cartridge cover
(3), cartridge sleeve
(4), metal o-ring (5)
& rubber washer (6).
Unscrew locking nut (7)
with wrench. Remove
cartridge (8). Check for
cracks