I N S TA L L AT I O N MA N UA L Nola™ Single Lever Commercial Style Kitchen Faucet KPF-1650 www.kraususa.com I toll free: 1.800.775.0703 I © 2014-2015 Kraus USA Inc. I REV.
Thank you for your purchase We would like to take this opportunity to thank you for choosing Kraus. We hope that you are completely satisfied with your purchase, and enjoy it for years to come. If you have any questions, or require technical assistance, please contact us at 800.775.0703 and one of our representatives will be happy to help. For more information about Kraus products, please visit: www.kraususa.
(147.3mm) 6 5/8” (168mm) 3/8” (10mm) 3 3/4” (96mm) 7/8” (22mm) Prior to Installation: 19.7º • Make sure you have all necessary parts by checking the diagram and parts 10 1/8” 8 5/16” list. If(257mm) any part is missing or damaged, please contact Kraus Customer (21mm) Service at 800-775-0703 for a replacement ∅ 1 15/16” (∅ 50mm) 1 3/8” Turn off the hot and cold water supply at the angle stops and turn on the (35mm) old faucet to release any built up pressure. Remove existing faucet.
Diagram and Parts List E A F B D G H I C1 C2 C3 A. Spray Head E. Hot & Cold Waterlines B. Faucet Body F. Aerator Key C. Mounting Hardware G. Faucet Extender (used for top C1. Rubber & Metal Washer mount sinks only) C2. Mounting Nut H. 2.5 mm Hex Wrench C3. Mounting Screw I. Deck Plate Assembly D.
26.2” (665mm) Faucet Dimensions 360º Ø35 35MAX Ø54 35MAX 7.2” (183mm) º 90 8.
Step 1: Remove mounting hardware Remove mounting hardware (C) from mounting B pipe D B C B D C C3 C E C E Step 2: Install faucet and mounting hardware A E E I C B D I C C 5 C2 Insert faucet body (B) into hole in countertop or sink.
Step 3: Secure mounting hardware Adjust the direction of faucet body (B).ETighten mounting E nut (C2) until snug. Tighten mounting screws (C3) to nut with a Phillips screwdriver until snug B C2 C3 B D Step 4: Connect waterlines B C E Connect waterlines (E) to copper lines and angle stops. Tighten both ends of waterlines with an adjustable wrench until snug.
C Step 5: Flush spray hose Remove spray head (A) from hose. Hold tip of hose.
Care & Maintenance *To keep the product clean & shining, follow the steps below: Close 25˚ Open 1. 2. 3. 4. Left 90˚Rinse with clean water & dry with a soft cloth Do not clean with soaps, acid, polish, abrasives, or harsh cleaners Push Do not use cloth with a coarse surface Unscrew the aerator and clean when necessary Hot Water *This installation manual is subject to change without further notice. Download the Kraus Care & Maintenance Guide at: http://www.kraususa.
Replacement Parts 1. A. Spray Head B. Check Valve 2. Washer 3 3. Spray Hose & Spring 4. Pivot Ring 5. Check Valve Connector 6. Set Screw 4 2 1B 7. Cover Button 18 1A 5 8. Set Screw 9. Metal Handle 19 10. Cartridge Cover 11. Locking Nut 20 12. Cartridge 6 13. Metal Base Ring 7 8 14. Rubber & Metal Washer 15. Mounting Nut 9 12 13 14 15 16 17 9 16. Mounting Screws 17. Faucet Extender 11 18. Aerator Key 10 19. 2.5 mm Hex Wrench 20. Hot & Cold Waterlines 21 21.
Trouble - Shooting If you have followed the instructions carefully and your faucet still does not work properly, take the following corrective steps: PROBLEM CAUSE ACTION Leaking from faucet handle Locking nut (11) may have come loose, or cartridge (12) may need to be reseated Remove cover button (7). Loosen set screw (8) with 2.5 mm hex wrench (19). Remove handle (9). Unscrew cartridge cover (10) by hand.
PROBLEM 11 CAUSE ACTION Leaking between spray head and hose Spray head (1A) may be loose or washer (2) may not be seated correctly in the hose connection Tighten spray head (1A) by hand until snug. Make sure washer (2) is seated correctly Low flow Check valve connector (5) may be clogged with debris Loosen set screw (6). Remove spray hose & spring (3). Unscrew check valve connector (5) located at bottom of spray hose & spring (3). Soak in 50/50 solution of warm water and vinegar for 5 minutes.
Maintenance - Cartridge Replacement Step 1: Remove button located at the top of the handle. Loosen the set screw with a hex wrench. Remove the handle and unscrew cartridge cover by hand Step 2: Unscrew the locking nut with an adjustable wrench. Remove ceramic disc cartridge Step 3: Place the new cartridge in the handle seat.
Codes/Standards Applicable: GREEN LEAD FREE IA P NSF/ANSI Standard 61 certified by IAPMO NSF/ANSI Standard 372 certified by IAPMO MO Meets ASME A112.18.1M/A112.18.1 R& T 1.75GPM 6.6L/min maximum TM Water Efficiency HELP LINE Our customer service hours are Monday – Friday, 9am – 8pm EST. Be sure to visit our website at www.kraususa.com If you are a homeowner please contact a Kraus Customer Service Representative at: Kraus USA, Inc.
www.kraususa.
R E G I S T E R Y O U R P R O D U C T T O D AY Receive Proof of Ownership Access Customer Care & Installation Help Get Exclusive Kraus Offers & Promotions Scan to Register Online or visit http://www.kraususa.com/registration We’re always looking for ways to improve. Please take a moment to share your experience. Visit http://www.kraususa.com/review to let us know what you think about your new Kraus product. Contact Us to Learn More 1.800.775.0703 / www.kraususa.com / customerservice@kraususa.