Trouble - Shooting
If you have followed the instructions carefully and your faucet still does not work
properly, take the following corrective steps:
PROBLEM CAUSE ACTION
Water will not shut off
completely
Cartridge(5) may need
to be adjusted or
replaced
Remove index button
(9B). Loosen set screw
(9A) with 2.5mm hex
wrench (15). Remove
metal handle (8).
Remove cartridge
cover (7) by hand only.
Remove locking nut
(6) with an adjustable
wrench. Remove ceramic
disc cartridge (5). Check
for cracks
Leaking from between
spray head and hose
Washer may be missing
or not seated correctly
in hose
Make sure washer is
present and seated
correctly in hose
Care & Maintenance
*To keep the product clean & shining, follow the steps below:
1. Rinse with clean water & dry with a soft cloth
2. Do not clean with soaps, acid, polish, abrasives, or harsh cleaners
3. Do not use cloth with a coarse surface
4. Unscrew the aerator and clean when necessary
*This installation manual is subject to change without further notice.
1
10
279
10 31/32”
Minimum distance 90mm
Less than 90mm
Cold Water
32 3/32”
Ø35~Ø38
1
2
3
10
9
11
12
13
Hexagon Nut
Hot
Water
Cold
Water
2 3
1
4
5
7
6
8
4
5
6
7
8
Ø1 3/8”~
Ø1 1/2”
815
194
7 5/8”
Ø1 3/8~Ø1 1/2”
30˚
10
11
Close
Open
Left
Hot Water
Push
25˚
90˚
12
13
8
7
Ø35~Ø38
Max35
217
8 17/32”
Max1 3/8”
9
11
12
13
2
3
4
5
6
7
8
Download the Kraus Care & Maintenance Guide at:
http://www.kraususa.com/maintenance