assembly Instructions

50
3.4 Safety instructions for work on electrical systems carried
out from the scaffold
Prior to carrying out any work on electrical systems and units, ensure that
the unit is disconnected from the power supply
the unit is secured against inadvertent switching on
all parts have been tested for residual voltage
the unit has been grounded and short-circuited
adjacent parts that remain powered are properly covered or cordoned off
3.5 Working near electric overhead lines
When working on electric overhead lines, maintain the following safety distances. The-
se safety distances prevent contact with swinging line cables and ensure that workers
using tools, etc. have sufcient room for movement. Safety distances according
to VDE 0105-100.
3.3 Safety instructions for the movement of the scaffold
The scaffold may only be moved, if it carries no persons and no material.
The scaffold must be moved by hand. Move it only over firm and level surfaces that
are free of obstacles.
The moving of the scaffold by means of a vehicle of any type is prohibited.
Do not move the scaffold at speeds that exceed the normal walking speed.
Move the scaffold only forward and back, and to the left and right, i.e. parallel to the
sides of the frame.
Ensure that the surface on which the scaffold is moved has the necessary load-
bearing capacity.
It is forbidden to lift or hoist the scaffold.
Do not move the scaffold at winds over strength 6 (~ 45 km/h).
Before using the scaffold, ensure that all necessary safety measures have been ta-
ken and that the scaffold it secured against inadvertent movement, e.g. by the appli-
cation of the brakes.
exceeded by the weight of the tools and materials. The use of lifting equipment is
prohibited.
The working platform must always be accessed as prescribed in this manual.
The bridging of gaps between the scaffold and building sections by means of planks
or similar equipment is prohibited. Do not use the scaffold as a climbing facility to
access other structures.