User Manual

19 Installation and operating instructions BM 702 (07/00)
6 Safety information
i
Hazardous-duty systems
Types of protection in the BM 702 terminal compartment:
Intrinsically safe"ia"
Consult the relevant wiring and installation regulations, e.g. VDE 0165, before
mounting, dismantling or making electrical connections in a hazardous area
Temperature rating of connecting cables:
The temperature rating of connecting cables is dependent on the maximum temperature of
the flange:
Version Max. flange
temperature
Cable temperature
rating
Without high temperature
100°C (212°F)
70°C (158°F)
distance piece > 100°C (212°F) 80°C (176°F)
With high temperature
200°C (212°F)
70°C (158°F)
i
distance piece > 200°C (212°F) 80°C (176°F)