Technical data extract
Application conditions
Temperature
Ambient temperature -40…+80°C / -40…+175°F;
EEx i: -40…+60°C / -40…+140°F
Storage temperature -40…+85°C / -40…+185°F
Flange temperature -40…+150°C / -40…+300°F (Viton gasket)
-20…+150°C / -5…+300°F (Kalrez 6375 gasket)
Thermal shock resistance 100°C/min
Process conditions
Operating pressure -1…40 bar / -14.5…580 psig;
subject to process connection used and flange
temperature
Dielectric constant 1.5
Vibration resistance IEC 68-2-6 and prEN 50178
(10...57Hz: 0.075 mm / 57...150 Hz: 1 g)
Protection category IP 66/67 equiv. to NEMA 6-6X
Output
Output signal
Output 1 4 … 20 mA HART® or 3.8 … 20.5 mA
acc. to NAMUR NE 43
Accuracy 0.05% (rel. 20 mA; 20°C / 68°F)
Resolution ±2 µA
Temperature drift Typically 50 ppm/K
Error signal High: 22 mA; Low: 3.6 mA acc. to NAMUR NE 43
Max. Load 350 ohm
Approvals
Overfill protection WHG
ATEX ATEX II G/D 1, 1/2, 2 EEx ia IIC T6;
ATEX II G/D 1/2, 2 EEx d ia IIC T6
FM IS class I Div. 1 Gr. A...G; XP class I Div. 1 Gr. A…G
CSA IS class I Div. 1 Gr. A...G; XP class I Div. 1 Gr. A…G
For futher data see data sheet, approvals and handbook on CD-ROM
Hotline: +33(0)4.75.05.44.00 · Fax: +33(0)4.75.05.44.97
www.krohne.com for local contacts · E-mail: level@krohne.fr