Display texts
Description and settings
inFo
dim. counter
Dimension of counters
Edit
m3
l
Gal.
"user unit"
Standard: m3
Select unit (dimension)
for positive, negative and sum counters.
inFo
disPL,Format
Display format
8.88888
88.8888
888.888
8888.88
88888.8
888888.
Auto.
"units see above"
Standard: 888888.
Select format for positive, negative and sum counters. The
first six settings have fixed positions for the decimal point. If
an off-scale indication occurs here, the marker flashes
against the displayed value. Off-scale indication can be
prevented by selecting a different format.
The setting “Automatic" will change the display such that
always the highest counter value is displayed, if necessary in
exponential format. An appropriate warning is shown when
an off-scale indication occurs, provided the display of
messages is activated in Function 1.4 “Display" setting
“Display of messages". A change of format will not alter the
value of the counter.
inFo
PoS cnt.disP.
Edit
YES
NO
Standard: No
inFo
neG cnt.disP.
Edit
YES
NO
Standard: No
inFo
Sum cnt.disP.
Edit
YES
NO
Standard: No
Positive counter display
Negative counter display
Sum counter display
The positive, negative and sum counter display functions
allow the respective counter to be switched on (Yes) or off
(No).
When several displays are selected, display of numerical
values is cyclic.
inFo
diSP.meSSaGeS
Display of messages
Edit
YES
NO
Standard: Yes
Setting as to whether, in addition, messages from self-test
functions are to be displayed (Yes) or not (No).