Manual

ALTOSONIC V
ModBus Manual 0300 rev07 E 7.30855.35.00 Page 30 of 64
24 B+R Totaliser standard: totaliser reset occurred 2 5
25 B+R Totaliser process: forward totaliser rollover occurred 1 5
26 B+R Totaliser process: reverse totaliser rollover occurred 1 5
27 B+R Totaliser standard: forward totaliser rollover occurred 2 5
28 B+R Totaliser standard: reverse totaliser rollover occurred 2 5
29 B+R Totaliser mass: sum totalizer rollover occurred 2 5
30 B+R Totaliser mass: totalizer reset occurred 2 5
31 B+R Totaliser mass: forward totalizer rollover occurred 2 5
32 B+R Totaliser mass: reverse totalizer rollover occurred 2 5
33 B+R Over range data path 1 1 5
34 B+R Over range data path 2 1 5
35 B+R Over range data path 3 1 5
36 B+R Over range data path 4 1 5
37 B+R Over range data path 5 1 5
38 B+R Path failure path 1 1 5
39 B+R Path failure path 2 1 5
40 B+R Path failure path 3 1 5
41 B+R Path failure path 4 1 5
42 B+R Path failure path 5 1 5
43 B+R Deviation in sound velocity path 1 1 5
44 B+R Deviation in sound velocity path 2 1 5
45 B+R Deviation in sound velocity path 3 1 5
46 B+R Deviation in sound velocity path 4 1 5
47 B+R Deviation in sound velocity path 5 1 5
48 B+R Communication failure path 1 1 5
49 B+R Communication failure path 2 1 5
50 B+R Communication failure path 3 1 5
51 B+R Communication failure path 4 1 5
52 B+R Communication failure path 5 1 5
53 B+R Real profile sampling on hold. By channel fails or flow dev 1 5
54 B+R Alarm on reading: external Viscosity 1 5 Default:not used
55 B+R Alarm on reading: temperature densitometer
2
5
56 B+R Alarm on reading: pressure densitometer
2
5
57 B+R Alarm on reading: temperature proving (external flowmeter)
8
5
58 B+R Alarm on reading: pressure proving (external flowmeter)
8
5
59 B+R Densitometer switch alarm
2
5
60 B+R Real profile out of range during correction of channel(s)
1
5
61 B+R Alarm on reading: standard density input
2
5
62 B+R Alarm on service value: temperature body
1
5
63 B+R Alarm on service value: temperature process
1
2 5
64 B+R Alarm on service value: temperature proving (ext flowm)
9
8 5
65 B+R Alarm on service value: temperature densitometer
9
5
66 B+R Alarm on service value: pressure process
9
5
67 B+R Alarm on service value: pressure proving (ext .flowm.)
9
8 5
68 B+R Alarm on service value: pressure densitometer
9
5
69 B+R Alarm on service value: densitometer density
9
5
70 B+R Alarm on service value: standard density
9
5
71 B+R Alarm on service value: viscosity external
9
5
72 B+R OVERRIDE enable possible for temperature body
1
7
73 B+R OVERRIDE enable possible for temperature process
2
7
74 B+R OVERRIDE enable possible for temperature proving (ext flowm)
8
7
75 B+R OVERRIDE enable possible for temperature densitometer
2
7
76 B+R OVERRIDE enable possible for pressure process
1
2 7