8.4 Field 3 (Read only Long Integer Field)
This data is read only and can be accessed with Modbus function 3 and 4 in Modbus slave mode and
with functions 6 and 16 in Modbus master mode.
By default the start addresses are mapped to address 5000 (default value)
start address
NotModiconComp
start address
ModiconComp
Type+Access
Description
Level
Level
Level
Remark
1 1 I32+R Resetable totaliser process sum 1 liter
2 3 I32+R Flow process 1
scaled -32768 ... +32767 ó
-125% …+125%
3 5 I32+R Sound velocity average 5
scaled 0…32767 ó
0…3276.7 m/s
4 7 I32+R resetable totaliser standard sum 2 liter
5 9 I32+R Flow standard 2
scaled -32768 … +32767 ó
-125%… +125%
6 11 I32+R Resetable totalizer mass sum 2 kg
7 13 I32+R Flow: mass 2
scaled -32768 … +32767 ó
-125%… +125%
8 15 I32+R UFP batch1 ticket count 4 0….2147483647
9 17 I32+R Resetable totaliser: process forward 1 liter
10 19 I32+R Resetable totaliser: process reverse 1 liter
11 21 I32+R Resetable totaliser: standard forward 2 liter
12 23 I32+R Resetable totaliser: standard reverse 2 liter
13 25 I32+R Resetable totaliser: mass forward 2 kg
14 27 I32+R Resetable totaliser: mass reverse 2 kg
15 29 I32+R UFP serial number 1 [ ]
16 31 I32+R Software version 1 [ ]
17 33 I32+R System set-up warning/error number 1 [ ]
18 35 I32+R System runtime warning/error number 1 [ ]
19 37 I32+R System messages 01...32 1 [ ]
20 39 I32+R System messages 33...64 1 [ ]
21 41 I32+R Resetable totaliser: external flowmeter actual total 8 liter
22 43 I32+R Resetable totaliser: external flowmeter standard total 8 liter
23 45 I32+R Resetable totaliser: external flowmeter mass total 8 kg
24 47 I32+R Process time (resets on totaliser reset) 5
s, used as watch dog for
host
25 49 I32+R Non resetable totaliser: process sum 1 0.1m3
26 51 I32+R Non resetable totaliser: process forward 1 0.1m3
27 53 I32+R Non resetable totaliser: process reverse 1 0.1m3
28 55 I32+R Non resetable totaliser: standard sum 2 0.1m3
29 57 I32+R Non resetable totaliser: standard forward 2 0.1m3
30 59 I32+R Non resetable totaliser: standard reverse 2 0.1m3
31 61 I32+R Non resetable totaliser: mass sum 2 0.1 ton
32 63 I32+R Non resetable totaliser: mass forward 2 0.1 ton
33 65 I32+R Non resetable totaliser: mass reverse 2 0.1 ton
34 67 I32+R Resetable totaliser: process sum (nett.oil) 3 liter
35 69 I32+R Resetable totaliser: process forward (nett.oil) 3 liter
36 71 I32+R Resetable totaliser: process reverse (nett.oil) 3 liter
37 73 I32+R Resetable totaliser: standard sum (nett.oil) 3 liter
38 75 I32+R Resetable totaliser: standard forward (nett.oil) 3 liter
39 77 I32+R Resetable totaliser: standard reverse (nett.oil) 3 liter
40 79 I32+R Resetable totaliser: mass sum (nett.oil) 3 kg