03/00 System Technology Remote Operation Instructions HART Communicator 275 Asset Management Solutions (AMS) BM100
BM100 Remote Operation - HC 275 / AMS Dev.-Rev. EE, DD-Rev. 03 CONTENTS 1 2 3 4 GENERAL INFORMATION 3 1.1 Configuring Instruments for Multidrop 3 1.2 Device Unique HART® Address 3 HART® TRANSMITTER REVISIONS AND INSTRUMENT FIRMWARE 3 2.1 Device Revisions 3 2.2 DD Revisions 3 HART® COMMUNICATOR 275 (HC275) 4 3.1 Installation 4 3.2 Operating 4 3.3 Known HC275 (4.6) Shortcomings 4 ASSET MANAGEMENT SOLUTIONS (AMS) 5 4.1 Installation 5 4.2 Operating 5 4.3 Known AMS (1.4.
BM100 Remote Operation - HC 275 / AMS Dev.-Rev. EE, DD-Rev. 03 1 General Information The BM100 is a two-wire transmitter with 4..20mA current output and HART® capability. General characteristics of the BM100 HART® interface: • Multidrop Mode is supported. • Burst Mode is not supported. Electrical connection (point-to-point or multidrop): refer to section Installation➪Wiring of the „Installation and Maintenance Manual. Reflex-Radar BM100“ and „Service Manual.
BM100 Remote Operation - HC 275 / AMS Dev.-Rev. EE, DD-Rev. 03 3 HART® Communicator 275 (HC275) 3.1 Installation The HC275 has to be programmed with the BM100 HART® Device Description (DD). Otherwise the HC275 user will work with the instrument as with a generic one thus loosing opportunity for entire instrument control. 3.2 Operating Refer to the BM100 Menu Tree HC275 (Attachment A). The BM100 operation via HC275 is made quite close to the manual instrument control via keypad.
BM100 Remote Operation - HC 275 / AMS Dev.-Rev. EE, DD-Rev. 03 4 Asset Management Solutions (AMS) 4.1 Installation • Refer to the “AMS Installation Guide” (Fisher Rosemount): “Installing Modems” (section 5) and “Wiring Diagrams” (appendix B). • AMS Configuration: If the BM100 Device Description is not already installed on the AMS System an „BM100 Device Installation Kit“ (on floppy disk / CD-ROM from KROHNE) is needed. For installing the DD with the Installation Kit refer: AMS 1.
BM100 Remote Operation - HC 275 / AMS Dev.-Rev. EE, DD-Rev. 03 • As compared with HC275 or PC-Star configuration tools, the BM100/AMS application has one additional function, being the HART® Common-Practice Apply values method. The latter assigns to the PV Upper/Lower Range Values the magnitude of the applied process. • Adjustment of the thresholds/gains (instrument’s functions 1.5.1, 1.5.4, Ser. 1.2.
BM100 Remote Operation - HC 275 / AMS Dev.-Rev. EE, DD-Rev.
BM100 Remote Operation - HC 275 / AMS Dev.-Rev. EE, DD-Rev. 03 Attachment A (continued from the previous page) BM100 Menu Tree HC275 1 Process Variables 1 Probe Length 2 Offset 3 Bottom Short-Cir. 4 Probe Position 5 Inter. Selection 1 Basis Parameters 1 Operation 2 Application 1 Measurement Mode 2 Reference 3 Serial I/O 1 Transmit 1 Operation 2 Configuration/ Test 2 Test Outputs 2 Calibration (M) 1 Derivative Refer. 2 Calibration I1,I2 (M) 3 Elec. Cal. Speed 4 Mech. Cal.
BM100 Remote Operation - HC 275 / AMS Dev.-Rev. EE, DD-Rev.
BM100 Remote Operation - HC 275 / AMS Dev.-Rev. EE, DD-Rev.