01/2001 System Technology Remote Operation Instructions HART Communicator 275 Asset Management Solutions (AMS) BM102
BM102 Remote Operation - HC 275 / AMS Dev.-Rev. EC, DD-Rev. 01 CONTENTS 1 GENERAL INFORMATION 3 2 HART® TRANSMITTER REVISIONS AND INSTRUMENT FIRMWARE 3 3 4 2.1 Device Revision 3 2.2 DD Revision 3 HART® COMMUNICATOR 275 (HC275) 4 3.1 Installation 4 3.2 Operating 4 3.3 Offline mode 4 ASSET MANAGEMENT SOLUTIONS (AMS) 5 4.1 Installation 5 4.2 Operating 5 4.
BM102 Remote Operation - HC 275 / AMS Dev.-Rev. EC, DD-Rev. 01 1 General Information The BM102 is a two-wire transmitter with 4..20mA current output and HART capability. General characteristics of the BM102 HART interface: • Multidrop Mode is supported. • Burst Mode is not supported. • The digital process value which is modulated on to the analog output signal as well as the analog value itself are low-pass filtered.
BM102 Remote Operation - HC 275 / AMS Dev.-Rev. EC, DD-Rev. 01 3 HART® Communicator 275 (HC275) 3.1 Installation The HC275 has to be programmed with the BM102 HART® Device Description (DD). Otherwise the HC275 user can only use the generic commands of the HC275 without being able to access the entire instrument control. 3.2 Operating Refer to the BM102 Menu Tree HC275 (Attachment A).
BM102 Remote Operation - HC 275 / AMS Dev.-Rev. EC, DD-Rev. 01 4 Asset Management Solutions (AMS) 4.1 Installation • Refer to the “AMS Installation Guide” (Fisher Rosemount): “Installing Modems” (section 5) and “Wiring Diagrams” (appendix B). • AMS Configuration: If the BM102 Device Description is not already installed on the AMS System an “BM102 Device Installation Kit” (on floppy disk / CD-ROM from KROHNE) is required. When installing the DD with the Installation Kit refer to: AMS 1.
BM102 Remote Operation - HC 275 / AMS Dev.-Rev. EC, DD-Rev. 01 and press ‘Apply’ again - otherwise the updated point(s) will be active only until the first power reset. Attention: While executing function “Re-Start BM102”, error messages could appear (“error reading xxx: field device did not respond”). This is due to the fact that AMS tries to refresh its values while the BM102 is not able to answer (initial self test : about 30 seconds).
BM102 Remote Operation - HC 275 / AMS Dev.-Rev. EC, DD-Rev. 01 5 Status Meaning • Meaning of General Status Messages: Status Message Configuration Changed More Status Available Meaning Appears whenever a configuration parameter is changed. Set when there is more information to read.
BM102 Remote Operation - HC 275 / AMS Dev.-Rev. EC, DD-Rev. 01 Not implemented First Parameter too high (first member of the couple too high) First Parameter too low (first member of the couple too low) Second Parameter too high (second member of the couple too high) Second Parameter too low (second member of the couple too low) © 2000 KROHNE SA 26103 Romans (France) device is in search mode or if it is executing a function. Appears if the command sent to the device is not implemented in the device.
BM102 Remote Operation - HC 275 / AMS Dev.-Rev. EC, DD-Rev. 01 6 Attachment A BM102 Menu Tree HC275 1 Process Var. 1 Level 2 Distance 3 Volume/Mass/Flow 4 Ullage Volume/ Mass/Flow 1 Measurements 2 Input/Outputs 1 Function I 2I 3% 1 Basis Parameters 1 Tank Height 2 Probe Length 3 Time Constant 4 Dead Zone 5 Sensor Info 1 Length 2 Display 2 Volume 1 Operation 2 Config.
BM102 Remote Operation - HC 275 / AMS Dev.-Rev. EC, DD-Rev. 01 Attachment A (continued from the previous page) BM102 Menu Tree HC275 1 Process Var. 1 Basis Parameters 1 Offset of Measure 2 Probe Type 3 Application Type 4 Epsilon R 1 Operation 2 Config./Test 2 Tests 2 Application 1 Voltage Values. (M) 2 Watch Pulses (M) 3 Meas. Stat. Hist. (M) 4 Problem History (M) 3 Service 3 Access Rights 4 Watch Status (M) 5 HART Variables 3 Calibration 4 EEPROM Reset 1 Current Output (M) 2 Elec. Cal.
BM102 Remote Operation - HC 275 / AMS Dev.-Rev. EC, DD-Rev.
BM102 Remote Operation - HC 275 / AMS Dev.-Rev. EC, DD-Rev.