Manual

KROHNE Messtechnik GmbH & Co. KG · Ludwig-Krohne-Str. 5 ! D-47058 Duisburg
9/10
Tel.: 0203-301 0 ! Fax: 0203-301 389 · e-mail: krohne@krohne.de
Remote Operation Instructions BM 70 A/P, BM 700, BM 702 HART
Attachment B
(continued from the previous page)
Process Variables
Status
Scan Device
-----------------------------------
Diagnostics and Test
Calibrate
-----------------------------------
Master reset
Entry Code
Service Code
-----------------------------------
Audit Trail
Drawing Notes ...
Help ...
-----------------------------------
Clear Offline Configuration
Compare Configurations
Configuration Properties
Designations:
Opt
– Optional, depends on device implementation;
Rd
– Read-only variable;
Loc
– Local AMS variable, affects only AMS faceplates and
confi
g
uration tabs and is not read/written from/to instrument.
BM 70 A/P /700 /702 Menu Tree AMS
KROHNE BM 70 A/P /700 /702 45f90b02
Hardware test
Loop test
Test relay
Opt
Calibration Management
-----------------------------------
D/A low trim
D/A high trim
Apply values
-----------------------------------
Autodetect tank height
Record tank empty spectrum
Basic Setup
Model
Rd
Tag
--------------------------------
Tank height
Tank type
Block distance
Antenna
Antenna Extension
--------------------------------
Time constant
--------------------------------
Function I
Scale 20 mA
Scale 4 mA
--------------------------------
Function S
Opt
Basis Parameters
Tank height
Block distance
Antenna
Distance piece
--------------------------------
Stillwell
ID Stillwell
--------------------------------
Reference offset
Tank bottom offset
Process Input
--Measurements/Cfg data--
Length unit
Length format
Loc
Conversion unit
Conversion format
Loc
----- Strap Table ------------
Level unit
Level format
Loc
Volume unit
Volume format
Loc
---------------------------------
Time constant
Analog Output
Function I
Range I
Scale 20 mA
Scale 4 mA
Device/HART
Model
Rd
Manufacturer
Rd
Field device revision
Rd
Software revision
Rd
Hardware revision
Rd
Firmware version
Rd
Firmware ident.nr.
Rd
Write protect
Rd
--------------------------------
Tag
Polling address
Device ID
Rd
Universal revision
Rd
Num request preams
Rd
Num response preams
Final asmby num
Date
Descriptor
Message
--------------------------------
PV is
SV is
TV is
4V is
Service
Min Peak
OF Threshold
HP Filter
Opt
LP Filter
Sweep
Opt
Empty spect. Type
Min Window
--------------------------------
Offset
Corr. Factor
Max Tankheight
Fct digital input
Opt
--------------------------------
Serial No
Option 1
Option 2
Relay Output
Function S
Opt
Type S
Opt
Threshold
Opt
Hysteresis
Opt
Application
Empty spectrum
Time constant
Tracing velocity
Mult. Reflections
BD Detect
Function FTB
Epsilon R
Tank type
Strap Table, 1-20
Number of points
First 20 pairs
Level
"
Volume
Strap Table, 41-50
Last 10 pairs
Level
"
Volume
Strap Table, 21-40
Next 20 pairs
Level
"
Volume