User Manual

55
5.7 Setting the frequency/pulse output (Fct. 3.4. and 1.4)
The frequency/pulse output allows the transfer of one of the following measurement values :
VALUE OUTPUT TYPE
Mass Total Pulse
Mass Flow Rate Frequency
Density Frequency
Temperature Frequency
Volume Total Pulse
Volume Flow Rate Frequency
Flow Direction Binary 0 or V+
For systems with the Concentration option, the following functions are also available:
VALUE OUTPUT TYPE
Concentration by mass / Brix Frequency
Concentration by volume Frequency
Solute flow / Brix rate Frequency
Solute Total Pulse
The exact programming of this output depends on the measurement value selected.
Pulse Outputs:
When the pulse output (Fct. 1.4.1 or 3.4.1) is set to either MASS TOTAL, VOL.TOTAL OR
SOL.TOTAL (Concentration systems only) then the following sub menus are available:
Fct. 3.4.1 FUNCTION P
Fct. 3.4.2 PULSE/MASS
( or PULSE/VOL. )
Fct. 3.4.3 PULSE.WIDTH