User's Manual

8 TECHNICAL DATA
48
OPTIWAVE 1010
www.krohne.com 09/2014 - 4003537401 - MA OPTIWAVE 1010 R01 en
8.2 Technical data
INFORMATION!
The following data is provided for general applications. If you require data that is more
relevant to your specific application, please contact us or your local sales office.
Additional information (certificates, special tools, software,...) and complete product
documentation can be downloaded free of charge from the website (Download Center).
Measuring system
Measuring principle 2-wire loop-powered level transmitter; C-band (6 GHz) FMCW radar
Application range Level measurement of clean liquids
Primary measured value Distance and reflection
Secondary measured value Level and volume
Design
Construction The measurement system consists of a wave guide connection and a signal
converter
Options Weather protection
Measuring range 0...5.3 m / 0...17.4 ft (max. 8 m / 26.2 ft on request)
Top dead zone Minimum value: 300 mm / 11.8¨ from the process connection
User interface
User interface PACTware
Measuring accuracy
Repeatability ±1mm/ ±0.04¨
Accuracy ±10 mm / ±0.4¨
Reference conditions acc. to EN 61298-1
Temperature +15...+25°C / +59...+77°F
Pressure 1013 mbara ±50 mbar / 14.69 psia ±0.73 psi
Relative air humidity 60% ±15%
Target Metal plate in an anechoic chamber