10.1 Order code
Make a selection from each column to get the full order code. The characters of the order code
highlighted in light grey describe the standard.
VF01 4 OPTIWAVE 1010 Non-Contact Radar (FMCW) Level Meter
Converter version (Housing material protection class)
1 OPTIWAVE 1010: Compact version (Aluminium IP 66/67)
2 OPTIWAVE 1010: Compact version (Stainless steel IP 66/67)
Approval 1
0 Without
1 ATEX Ex ia IIC T3T6 + DIP 2
2 ATEX Ex d ia IIC T3..T6 + DIP 2
4 ATEX Ex ic IIC T3T6 + DIP 2
6 IECEx Ex ia IIC T3T6 + DIP 2
7 IECEx Ex d ia IIC T3T6 + DIP 2
8 IECEx Ex ic IIC T3T6 + DIP 2
A cFMus IS CL I/II/III, DIV 1, GPS A-G; CL I, Zone 0/20, Ex ia IIC/IIIC T3T6
B cFMus XP-IS/DIP CL I/II/III, DIV 1, GPS A-G (A not for CAN); CL I, Zone 0/20, Ex d/tb IIC/IIIC T3T6
C cFMus NI CL I/II/III, DIV 2, GPS A-G; CL I, Zone 2, Ex nA IIC T3...T6
L NEPSI Ex ia IIC T3 ~ T6 + DIP 2
M NEPSI Ex d ia IIC T3 ~ T6 + DIP 2
Other approval
0 Without
4 CRN (Canadian Registration Number)
A WHG
Process seal Temperature / Pressure / Material / Remarks (material to be checked by the
customer)
0 Without
1 -40°C...+100°C (-40°F+212°F) / -116 barg (-14.5232 psig) / FKM/FPM
2 -50°C...+100°C (-58°F+212°F) / -116 barg (-14.5232 psig) / EPDM
3 -20°C...+100°C (-4°F+212°F) / -116 barg (-14.5232 psig) / Kalrez® 6375
5 -40°C...+150°C (-40°F+302°F) / -1...40 barg (-14.5580 psig) / FKM/FPM 3
6 -50°C...+150°C (-58°F+302°F) / -1...40 barg (-14.5580 psig) / EPDM 3
7 -20°C...+150°C (-4°F+302°F) / -1...40 barg (-14.5580 psig) / Kalrez® 6375 3
VF01 4 Order code (complete this code on the pages that follow)