INSTALLATION
3
35
OPTIWAVE 7400-24 C
www.krohne.com12/2015 - 4004901901 - MA OPTIWAVE7400-24 R01 fr
3mm Allen wrench
3.9 How to turn or remove the signal converter
3.10 How to assemble the remote version
Attach the wall bracket 1 to the flexible conduit.
Tighten the locking nut 2 with a 24 mm wrench.
Attach the wall bracket to a wall or pipe (DN50...100 / 2¨...4¨) 3.
Loosen the housing locking screw 4 with a 5 mm Allen wrench.
Remove the housing 5.
INFORMATION!
The converter turns 360
°
. The converter can be removed from the process connection assembly
under process conditions.
Figure 3-17: How to turn or remove the signal converter
1 Tool: 5 mm Allen wrench (not supplied)
2 Cover for the wave guide hole on top of the process connection assembly (not supplied)
CAUTION!
If you remove the converter, put a cover on the wave guide hole on top of the process connection
assembly.
When the converter is attached to the process connection assembly, tighten the lock screw.