ELECTRICAL CONNECTIONS
4
41
OPTIWAVE 7400-24 C
www.krohne.com12/2015 - 4004901901 - MA OPTIWAVE7400-24 R01 fr
Basic properties
Twisted cable 2 by 2, shielded or screened. For example, multicore cable reference
MCD 5123 from Cabletec ICS/JP Electronics.
Maximum length of the signal cable
100 m / 328 ft
Temperature
Use electrical cable with the applicable temperature rating for the operating conditions.
Ambient temperature range: -40...+80°C / -40...+175°F
We recommend that the cable agrees with UL 94V-0.
Dimensions of the insulated conductors
Min.-max. cross-sectional area of the conductors: 4×0.326...4×2.5 mm² (22....14 AWG),
shielded cable
Use the applicable cable for the cable glands (Ø6....10 mm / 0.24...0.39¨).
Use the applicable cable glands for the cable entry openings in the housing.
Electrical characteristics
Test voltage: Insulated conductor / shield (screen) 500 VAC
Line resistance: < 55 Ω/km
The cable must agree with EN 60811 (Low Voltage Directive) or equivalent national