Manual

4 ELECTRICAL CONNECTIONS
32
IFC 050
www.krohne.com 08/2013 - 4002184002 - MA IFC 050 R02 en
4.9 Description of the outputs
4.9.1 Current output
All outputs are electrically isolated from each other and from all other circuits.
All operating data and functions can be adjusted.
Passive mode: external power U
ext
32 VDC at I 22 mA
Active mode: load impedance R
L
750 Ω at I 22 mA
Self-monitoring: interruption or load impedance too high in the current output loop
Error message possible via status output, error indication on LC display.
Current value error detection can be adjusted.
Automatic range conversion via threshold. The setting range for the threshold is between 5
and 80% of Q
100%
, ± 0...5% hysteresis (corresponding ratio from smaller to larger range of
1:20 to 1:1.25).
Signaling of the active range possible via a status output (adjustable).
Forward / reverse flow measurement (F/R mode) is possible.
INFORMATION!
Depending on the version, the outputs must be connected passively or actively!
INFORMATION!
For further information refer to Connection diagrams of outputs on page 36
and refer to
Technical data on page 71
.