ELECTRICAL CONNECTIONS 4
39
IFC 050
www.krohne.com08/2013 - 4002184002 - MA IFC 050 R02 en
Pulse/frequency output passive
U
ext
32 VDC
f
max
in the operating menu set to f
max
100 Hz:
I 100 mA
R
L
47 kΩ
closed:
U
0
0.2 V at I = 10 mA
U
0
2 V at I = 100 mA
open:
I 0.05 mA at U
ext
= 32 V
f
max
in operating menu set to 100 Hz < f
max
10 kHz:
(over range up to f
max
12 kHz)
I 20 mA
R
L
10 kΩ for f 1kHz
R
L
1kΩ for f 10 kHz
closed:
U
0
1.5 V at I = 1 mA
U
0
2.5 V at I = 10 mA
U
0
5 V at I = 20 mA
open:
I 0.05 mA at U
ext
= 32 V
Use shielded cables!
The minimum load impedance R
L, min
is calculated as follows:
R
L, min
=(U
ext
-U
0
)/I
max
Can also be set as status output; for the electrical connection refer to status output
connection diagram.
INFORMATION!
For frequencies above 100 Hz, shielded cables are to be used in order to reduce effects from
electrical interferences (EMC).
Shielding takes place at the electrical connection (S) of the output terminal block.
INFORMATION!
Independent of connection polarity.
The output is open if the signal converter is not powered.
Figure 4-15: Pulse/frequency output passive P
p