Manual

4 ELECTRICAL CONNECTIONS
40
IFC 050
www.krohne.com 08/2013 - 4002184002 - MA IFC 050 R02 en
Pulse/frequency output active
U
int, nom
20 V
R
V
=1kΩ
C = 1000 µF
High current mechanical counter
High current mechanical counterHigh current mechanical counter
High current mechanical counter
f
max
1Hz
Low current mechanical counter
Low current mechanical counterLow current mechanical counter
Low current mechanical counter
I 20 mA
R
L
10 kΩ for f 1kHz
R
L
1kΩ for f 10 kHz
closed:
U
0
12.5 V at I = 10 mA
open:
I 0,05 mA at U
nom
= 20 V
INFORMATION!
The active output is galvanically coupled with the current output.
This output is intended to drive directly mechanical or electronic counters.
Figure 4-16: Pulse/frequency output active P
a