Manual
6 OPERATION
48
IFC 050
www.krohne.com 08/2013 - 4002184002 - MA IFC 050 R02 en
6.3 Menu structure
INFORMATION!
•
The menu structure for the standard device is described.
•
Special functions for Modbus are described in detail in the corresponding supplementary
instructions.
•
Note the key function within and between the columns.
Measuring mode Select
menu
↓
↑
Select menu and/or submenu
↓ ↑
Select
function
and set
data
↓ ↑ >
^ Press
>2.5s
A quick setup >
^
A1 language >
^
- >
^
A2 HART >
^
A2.1 tag
A3 RS 485 / Modbus >
^
A3.1 tag
A3.2 slave address
A4 reset >
^
A4.1 reset errors
A4.2 counter 1
A4.3 counter 2
A5 analogue outputs >
^
A5.1 range
A5.2 time constant
A5.3 low flow cutoff
A6 digital outputs >
^
A6.1 max. pulse rate
A6.2 pulse value unit
A6.3 value p. pulse
A7 process input >
^
A7.1 device serial no.
A7.2 zero calibration
A7.3 size
A7.4 GKL
A7.5 field frequency
A7.6 flow direction
^ B test >
^
B1 simulation >
^
For details about the
submenus refer to
Menu
B, test
on page 52
>
^
B2 actual values
B3 information
↓ ↑ ↓ ↑ ↓ ↑ ↓ ↑ >