Manual

6 OPERATION
50
IFC 050
www.krohne.com 08/2013 - 4002184002 - MA IFC 050 R02 en
6.4 Function tables
6.4.1 Menu A, quick setup
INFORMATION!
The functions for the standard device are described in the following tables.
Special functions for Modbus are described in detail in the corresponding supplementary
instructions.
Depending on the device version, not all functions are available.
No. Function Setting / Description
A1 language
A1 language Language selection depends on the device version.
A2 HART
A2.1 tag Measuring point identifier (Tag no.) appears in the LC display header (up to 8
digits).
A3 RS485/Modbus
A3.1 tag Measuring point identifier (Tag no.) appears in the LC display header (up to
16 digits). The first 8 digits are identical to the HART
®
measuring point (see
above).
A3.2 slave address Setting the device address at the Modbus interface.
A4 reset
A4.1 reset errors reset errors?
Select: no/yes
A4.2 counter 1 reset counter?
Select: no / yes (available if activated in C5.9.1)
A4.3 counter 2 reset counter?
Select: no / yes (available if activated in C5.9.2)
A5 analogue outputs
A5.1 range Measuring range for the analogue outputs (current output, frequency output
and display)
A5.2 time constant Time constant for the analogue outputs (current output, frequency output
and display)
A5.3 low flow cutoff Low flow cutoff for the analogue outputs (current output and frequency
output)