3.8 Overview of outputs
3.8.1 Description of the CG number
3.8.2 Fixed, non-alterable output versions
This signal converter is available with various output combinations.
• The grey boxes in the tables denote unassigned or unused connection terminals.
• In the table, only the final digits of the CG-No. are depicted.
• Connection terminal A+ is only operable in the basic output version.
Description of used abbreviations
Figure 3-13: Marking (CG number) of the electronics module and output variants
1 ID number: 0
2 ID number: 0 = standard; 9 = special
3 Power supply
4 Display (language versions)
5 Output version
CG-No. Connection terminals
A+ A A- C C- D D-
Basic outputs (I/O) Standard
1 0 0
I
p
+ HART
®
passive 1
S
p
passive P
p
/ S
p
passive 2
I
a
+ HART
®
active 1
1 function changed by reconnecting
2 changeable
I
a
I
p
Current output active or passive
P
p
Pulse/frequency output passive
S
p
Status output / limit switch passive