Quickstart EN Instruction Manual

ELECTRICAL CONNECTIONS 3
55
IFC 300
www.krohne.com08/2010 - 4000070303 - QS IFC 300 R06 en
3.9 Inputs and outputs, overview
3.9.1 Combinations of the inputs/outputs (I/Os)
This signal converter is available with various input/output combinations.
Basic version
Has 1 current output, 1 pulse output and 2 status outputs / limit switches.
The pulse output can be set as status output/limit switch and one of the status outputs as a
control input.
Ex i version
Depending on the task, the device can be configured with various output modules.
Current outputs can be active or passive.
Optionally available also with Foundation Fieldbus and Profibus PA
Modular version
Depending on the task, the device can be configured with various output modules.
Bus systems
The device allows intrinsically safe and non intrinsically safe bus interfaces in combination
with additional modules.
For connection and operation of bus systems, please note the separate documentation.
Ex option
For hazardous areas, all of the input/output variants for the housing designs C and F with
terminal compartment in the Ex d (pressure-resistant casing) or Ex e (increased safety)
versions can be delivered.
Please refer to the separate instructions for connection and operation of the Ex-devices.